    Ill-Conditioned Inverse Problems

    Can an accurate Euclidean correlator determine a spectral density? It can constrain some combinations of spectral weight very well while leaving others almost invisible. More precise arithmetic helps evaluate those combinations, but it cannot supply missing observations.

    We will construct two different positive, normalized, continuous spectra with exactly the same sixteen correlator values. We will then give the spectrum a definite norm, whiten the observational errors, and use singular values to distinguish missing information from numerical rounding.

    Preparation: covariance and singular-value decomposition; the spectral interpretation of Euclidean correlators and the retarded convention. The next article develops correlated fitting and regularization.

    A positive spectrum with an exact transform

    Choose an energy unit, and express energies and reciprocal times in those units. Our finite benchmark is

    C(t)=∫04s(E)e−tE dE,s(E)≥0,∫04s(E) dE=1.C(t)=\int_0^4 s(E)e^{-tE}\,dE, \qquad s(E)\geq0, \qquad \int_0^4s(E)\,dE=1.

    For a connected Hermitian channel at zero temperature, the positive spectral measure has this Laplace form. With the site's definition GR=−iθ⟨[O,O]⟩G_R=-i\theta\langle[O,O]\rangle, its positive-frequency commutator density is ρ(E)=2πs(E)\rho(E)=2\pi s(E). Compact support and unit total weight are additional information supplied to this example. They are not universal sum rules for local QFT operators. Finite-volume spectra can instead be sums of atoms; fixed smearing is then a useful target before a volume limit. Hansen, Lupo and Tantalo, §I, Eqs. (3)–(7).

    Use a triangular peak

    pb(E;μ)=(1−∣E−μ∣/b)+b.p_b(E;\mu)=\frac{(1-|E-\mu|/b)_+}{b}.

    It is the distribution of μ+X+Y\mu+X+Y, where X,YX,Y are independent uniforms on [−b/2,b/2][-b/2,b/2]. Therefore

    ∫pb(E;μ)e−tE dE=e−μt[sinh⁡(bt/2)bt/2]2.\int p_b(E;\mu)e^{-tE}\,dE =e^{-\mu t}\left[\frac{\sinh(bt/2)}{bt/2}\right]^2.

    The quotient has value one at t=0t=0. This derivation also gives the mean μ\mu, variance b2/6b^2/6, and unit normalization. The exact continuous transform generates the data; a reconstruction grid does not generate its own answers.

    For the chapter's principal inference experiment, set

    s(E;d,w)=w p0.2(E;2−d/2)+(1−w)p0.2(E;2+d/2),0.4≤d≤1.6,0.2≤w≤0.8.\begin{aligned} s(E;d,w)&=w\,p_{0.2}(E;2-d/2) +(1-w)p_{0.2}(E;2+d/2),\\ 0.4&\leq d\leq1.6,\qquad 0.2\leq w\leq0.8. \end{aligned}

    The primary truth is (d,w)=(1.2,0.6)(d,w)=(1.2,0.6). Observations occur at ti=0.15it_i=0.15i, for i=1,…,16i=1,\ldots,16. Their known covariance is

    Σij(δ)=δ2CirefCjrefRij,Rij=12e−∣i−j∣/2+12δij,\begin{aligned} \Sigma_{ij}(\delta) &=\delta^2C_i^{\rm ref}C_j^{\rm ref}R_{ij},\\ R_{ij}&=\tfrac12e^{-|i-j|/2}+\tfrac12\delta_{ij}, \end{aligned}

    where CrefC^{\rm ref} is the primary truth at the nominal times. The main noise level is δ=0.01\delta=0.01. This covariance describes one observed vector y=C+ϵy=C+\epsilon, with ϵ∼N(0,Σ)\epsilon\sim N(0,\Sigma). It stays fixed as parameters are fitted. There is no additional, unspecified number of configurations.

    Two positive spectra that finite exact data cannot distinguish

    Positivity and normalization do not reduce the space of all spectra to the two-parameter family above. Here is an explicit alternative construction.

    Take eighteen triangles of width b=0.2b=0.2, with centers

    μj=0.3+0.2j,j=0,…,17.\mu_j=0.3+0.2j,\qquad j=0,\ldots,17.

    Add t0=0t_0=0 to the sixteen observation times, so that normalization is one of the constraints. Put

    zi=e−0.2ti,P(z)=∏i=016(z−zi)=∑j=017vjzj.\begin{aligned} z_i&=e^{-0.2t_i},\\ P(z)&=\prod_{i=0}^{16}(z-z_i) =\sum_{j=0}^{17}v_jz^j. \end{aligned}

    At any observed time, every component transform contains the same factor, and

    ∑jvjCj(ti)=e−0.3ti[sinh⁡(0.1ti)0.1ti]2∑jvj(e−0.2ti)j=e−0.3ti[sinh⁡(0.1ti)0.1ti]2P(zi)=0.\begin{aligned} \sum_jv_j C_j(t_i) &=e^{-0.3t_i} \left[\frac{\sinh(0.1t_i)}{0.1t_i}\right]^2 \sum_jv_j(e^{-0.2t_i})^j\\ &=e^{-0.3t_i} \left[\frac{\sinh(0.1t_i)}{0.1t_i}\right]^2P(z_i)=0. \end{aligned}

    The continuous value of the prefactor is understood at i=0i=0. In particular, ∑jvj=P(1)=0\sum_jv_j=P(1)=0.

    Now define

    α=0.918max⁡j∣vj∣,wj±=118±αvj,s±(E)=∑jwj±p0.2(E;μj).\begin{aligned} \alpha&=\frac{0.9}{18\max_j|v_j|},\\ w_j^\pm&=\frac1{18}\pm\alpha v_j,\\ s_\pm(E)&=\sum_jw_j^\pm p_{0.2}(E;\mu_j). \end{aligned}

    Every weight is at least 0.1/180.1/18. Both spectra are normalized, strictly positive in the interior (0.1,3.9)(0.1,3.9), and zero outside their support. They differ because the nonzero polynomial coefficients give a nonzero combination of these triangular basis functions. Nevertheless,

    C+(ti)=C−(ti),i=0,…,16.C_+(t_i)=C_-(t_i),\qquad i=0,\ldots,16.

    This is exact nonuniqueness of finite observations. The example does not assert that two different members of the restricted two-peak family have identical data. Assuming that smaller family supplies substantial extra information.

    The companion computes the coefficients at 80 and 120 decimal digits. The largest transform difference is 2.65×10−822.65\times10^{-82} and 7.62×10−1237.62\times10^{-123}, respectively. These are numerical evaluations of the analytic identity, not replacements for its proof. After rounding weights and evaluating in binary64, the largest difference is 2.22×10−162.22\times10^{-16}; its covariance-weighted distance at δ=0.01\delta=0.01 is only 1.73×10−131.73\times10^{-13}.

    The density difference is substantial:

    ∥s+−s−∥L2=0.260638.\lVert s_+-s_-\rVert_{L^2}=0.260638.

    An independent check uses the triangle Gram matrix. Its diagonal entries are 2/(3b)2/(3b); adjacent centers, separated by bb, have overlap 1/(6b)1/(6b); all other overlaps vanish. This reproduces the piecewise-quadrature squared distance 0.06793210.0679321.

    Two distinct positive triangular-mixture spectra with identical finite Laplace data, beside the rapidly decreasing singular values of the whitened kernel.

    The two spectra have identical exact data at the sixteen stated times and the same normalization. The singular-value panel uses the separately declared L2L^2 spectral metric and δ=0.01\delta=0.01. The smallest binary64 singular values differ from fresh high-precision values; increasing precision does not remove the exact positive ambiguity.

    Singular values need a spectral metric and a noise metric

    A matrix condition number is not yet a statement about physically distinguishable spectra. Its meaning depends on the units and norm of both input and output.

    Divide [0,4][0,4] into MM bins of width h=4/Mh=4/M, and use

    ej(E)=1[Ej,Ej+1)(E)h,sM(E)=∑jxjej(E).e_j(E)=\frac{\mathbf1_{[E_j,E_{j+1})}(E)}{\sqrt h}, \qquad s_M(E)=\sum_jx_je_j(E).

    Then ∥sM∥L22=xTx\lVert s_M\rVert_{L^2}^2=x^Tx. The bin mass is mj=h xjm_j=\sqrt h\,x_j. The exact bin-integrated kernel is

    Kij=e−tiEj−e−tiEj+1tih.K_{ij} =\frac{e^{-t_iE_j}-e^{-t_iE_{j+1}}}{t_i\sqrt h}.

    For small tiht_ih, evaluate the difference with expm1⁡(−tih)\operatorname{expm1}(-t_ih) to avoid subtracting nearly equal exponentials.

    Normalization becomes aTx=1a^Tx=1, with aj=ha_j=\sqrt h. Let xrefx_{\rm ref} represent the uniform density, and let the columns of ZZ be orthonormal with aTZ=0a^TZ=0. Write

    x=xref+Zz.x=x_{\rm ref}+Zz.

    If Σ=LLT\Sigma=LL^T is a Cholesky factorization, whiten the residual:

    dy=L−1(y−Kxref),A=L−1KZ=U diag⁡(σk)VT.\begin{aligned} d_y&=L^{-1}(y-Kx_{\rm ref}),\\ A&=L^{-1}KZ=U\,\operatorname{diag}(\sigma_k)V^T. \end{aligned}

    The whitened noise has covariance II. In a singular direction,

    ukTdy=σkvkTz+ηk,Var⁡(ηk)=1.u_k^Td_y=\sigma_k v_k^Tz+\eta_k, \qquad \operatorname{Var}(\eta_k)=1.

    Dividing by a small σk\sigma_k amplifies noise. A perturbation of unit L2L^2 norm along that direction has data separation σk\sigma_k, in standard-noise units. This does not imply that counting σk>1\sigma_k>1 counts resolved peaks: actual spectral amplitudes, positivity, normalization and the target all matter.

    If one instead represents the spectrum by masses mjm_j, the correct norm is ∑jmj2/h\sum_jm_j^2/h. Using an unweighted Euclidean mass norm changes the question and rescales the singular values by 1/h1/\sqrt h. With the matching metric, the mass and density representations give the same operator. The companion verifies this equivalence directly. SVD filters and the discrete Picard condition are discussed in P. C. Hansen, §§2.2–2.4 (PDF).

    More digits distinguish arithmetic error from missing information

    At M=40M=40 and δ=0.01\delta=0.01, the first singular value is 2362.402362.40. Several small values are

    DirectionBinary64Fresh 90-digit assembly
    k=13k=135.83661×10−115.83661\times10^{-11}5.83624×10−115.83624\times10^{-11}
    k=14k=141.43401×10−121.43401\times10^{-12}1.42981×10−121.42981\times10^{-12}
    k=15k=151.48519×10−131.48519\times10^{-13}2.68124×10−142.68124\times10^{-14}
    k=16k=161.03538×10−131.03538\times10^{-13}3.34392×10−163.34392\times10^{-16}

    Fresh 50- and 90-digit calculations agree to a maximum relative difference below 3×10−343\times10^{-34}. These calculations reconstruct the declared decimal inputs, covariance and matrix operations at the new precision.

    A different experiment promotes the already rounded binary64 matrix to high precision. Its last singular value remains 1.01655×10−131.01655\times10^{-13}. More accurate factorization of that matrix cannot undo information lost during its assembly. Conversely, neither experiment supplies information absent from the sixteen observations.

    At M=80M=80 and M=160M=160, the leading singular values approach stable values while binary64 still has a small-value floor. Grid refinement therefore has two separate roles: improving the finite representation of a spectrum and changing the numerical conditioning of the inverse. A stable forward calculation does not imply a stable reconstruction.

    The source-distribution companion reproduces the positive pair, independent integrals and precision comparison:

    python3 examples/computational-qft/inverse-problems/spectral_conditioning.py
    

    Its selected outputs are retained in the adjacent conditioning-results.json. This finite benchmark is not a reconstruction from measured lattice data.

    Summary

    Finite Laplace data can admit distinct positive normalized spectra even without noise. Whitening and an explicit spectral norm make singular directions quantitatively interpretable. High precision can separate matrix-rounding errors from tiny singular values, but it cannot resolve exact nonuniqueness or statistical indistinguishability. A useful reconstruction must state its additional assumptions and the quantity it seeks to estimate.

    Exercises

    1. A three-peak positive ambiguity

    Place three equal-width triangles at μ0\mu_0, μ0+Δ\mu_0+\Delta and μ0+2Δ\mu_0+2\Delta, inside the support. Suppose only normalization and C(τ)C(\tau) are known. Set r=e−τΔr=e^{-\tau\Delta}. Construct two positive mixtures with these same data.

    Solution

    The component transforms at τ\tau are a common positive factor times (1,r,r2)(1,r,r^2). The vector

    v=(r,−(1+r),1)v=(r,-(1+r),1)

    obeys v⋅(1,1,1)=0v\cdot(1,1,1)=0 and v⋅(1,r,r2)=0v\cdot(1,r,r^2)=0. Equivalently, its coefficients form (z−1)(z−r)(z-1)(z-r).

    Starting from weights (1/3,1/3,1/3)(1/3,1/3,1/3), choose

    w±=(1/3,1/3,1/3)±ϵv,0<ϵ<13(1+r).w^\pm=(1/3,1/3,1/3)\pm\epsilon v, \qquad 0<\epsilon<\frac{1}{3(1+r)}.

    All weights remain positive, both sums equal one, and both measured transforms coincide. The resulting spectra differ. An additional observation at a generic different time breaks this particular one-dimensional ambiguity, but does not make finitely many observations determine an unrestricted continuous density.

    2. What does a small data separation mean?

    Two fixed candidate spectra predict means C1,C2C_1,C_2 with the same known Gaussian covariance Σ\Sigma. Their prior probabilities are equal. Derive the optimal classification error in terms of

    D2=(C1−C2)TΣ−1(C1−C2).D^2=(C_1-C_2)^T\Sigma^{-1}(C_1-C_2).
    Solution

    Whiten with Σ=LLT\Sigma=LL^T, and put v=L−1(C1−C2)v=L^{-1}(C_1-C_2). The Gaussian log-likelihood ratio is

    ℓ(y)=vTL−1[y−C1+C22].\ell(y)=v^TL^{-1}\left[y-\frac{C_1+C_2}{2}\right].

    Under candidate one, ℓ\ell has mean D2/2D^2/2 and variance D2D^2; under candidate two its mean is −D2/2-D^2/2. Choosing candidate one when ℓ>0\ell>0 gives equal conditional errors

    Perror=Φ(−D/2).P_{\rm error}=\Phi(-D/2).

    For D=0D=0, the distributions are identical and the error is 1/21/2. For D≪1D\ll1, classification is barely better than guessing. More digits can help compute DD accurately; they do not reduce the physical covariance or create another observation. The conclusion concerns these two fixed candidates and this stated Gaussian experiment, not every possible prior or measurement.

    References

    • M. Hansen, A. Lupo and N. Tantalo, “On the extraction of spectral densities from lattice correlators,” Physical Review D 99, 094508 (2019), arXiv:1903.06476v2, §I, Eqs. (3)–(7). Positive spectral measures and fixed smearing.
    • P. C. Hansen, Regularization Tools: A Matlab Package for Analysis and Solution of Discrete Ill-Posed Problems, Version 4.1 (March 2008), author's manual (PDF), §§2.2–2.4, printed pp. 11–18. Norms, singular values, filter factors and the Picard condition.

    Scrollable formula. Use Left and Right arrow keys to reveal hidden content.

    Scrollable table. Use Left and Right arrow keys to reveal hidden columns.

    Scrollable figure. Use Left and Right arrow keys to reveal hidden content.