Skip to content
QFT.org

Search QFT.org

Enter a word or phrase.

    You can also browse the main navigation and chapter contents.

    A state can have zero mean stress and nonzero stress fluctuations. To measure those fluctuations one must specify a spacetime or worldline resolution: the formal variance of stress at one point is not finite. A Gaussian-smeared chiral energy gives an exact example, and a coherent pulse shows how its noise differs from its mean.

    Preparation: Quasifree states supplies Wick factorization. Point splitting defines the renormalized stress itself. The explicit calculation uses the derivative field of one free massless scalar in two-dimensional Minkowski space.

    Centering and smearing the stress

    Define t^ab(x)=T^ab(x)−⟨T^ab(x)⟩1\hat t_{ab}(x)=\hat T_{ab}(x)-\langle\hat T_{ab}(x)\rangle\mathbf1. The noise kernel is the real symmetric bi-distribution

    Nab,c′d′(x,y)=12⟨{t^ab(x),t^c′d′(y)}⟩.N_{ab,c'd'}(x,y) =\frac12\left\langle \{\hat t_{ab}(x),\hat t_{c'd'}(y)\}\right\rangle.

    Primed indices belong to yy. For a real smooth compact sampler fabf^{ab},

    t^(f)=∫ddx∣g∣ fab(x)t^ab(x),N(f,f)=⟨t^(f)2⟩≥0.\hat t(f)=\int d^dx\sqrt{|g|}\,f^{ab}(x)\hat t_{ab}(x), \qquad N(f,f)=\langle\hat t(f)^2\rangle\ge0.

    Finite local c-number changes in T^\hat T cancel on centering. The kernel retains its distributional singularities on coincident and null-related points; centering does not turn it into a smooth pointwise covariance. These definitions and qualifications are developed in Hu and Verdaguer, §3.2, Eqs. (3.11)–(3.12).

    For a Gaussian field, Wick's theorem expresses the separated connected stress correlator through products of derivatives of W(x,y)W(x,y). A general non-Gaussian state also needs its connected four-point function. The anticommutator gives noise; the commutator supplies causal response. They contain different information except when extra conditions, such as stationarity and a thermal relation, connect them.

    A chiral vacuum variance

    Use u=t−xu=t-x, v=t+xv=t+x and j(u)=∂uϕj(u)=\partial_u\phi. The current vacuum two-point function and normal-ordered stress are

    ⟨j(u)j(u′)⟩=−14π(u−u′−i0)2,T(u)=:j(u)2:.\langle j(u)j(u')\rangle =-\frac1{4\pi(u-u'-i0)^2}, \qquad T(u)=\mathopen{:}j(u)^2\mathclose{:}.

    The derivative field avoids the scalar zero-mode ambiguity. Wick contraction gives

    ⟨T(u)T(u′)⟩c=18π2(u−u′−i0)4=148π2∫0∞dk k3e−ik(u−u′−i0).\langle T(u)T(u')\rangle_c =\frac1{8\pi^2(u-u'-i0)^4} =\frac1{48\pi^2}\int_0^\infty dk\,k^3e^{-ik(u-u'-i0)}.

    The last equality is the boundary value of the convergent Laplace integral with positive regulator. It fixes the sign and coefficient without treating the fourth-order pole as an ordinary integrable function.

    Choose

    fτ(u)=e−u2/τ2πτ,T(fτ)=∫du fτ(u)T(u),f^τ(k)=e−τ2k2/4.f_\tau(u)=\frac{e^{-u^2/\tau^2}}{\sqrt\pi\tau}, \qquad T(f_\tau)=\int du\,f_\tau(u)T(u), \qquad \widehat f_\tau(k)=e^{-\tau^2k^2/4}.

    The vacuum mean vanishes, while the variance is

    Var⁡0T(fτ)=148π2∫0∞dk k3∣f^τ(k)∣2=124π2τ4.\operatorname{Var}_0 T(f_\tau) =\frac1{48\pi^2}\int_0^\infty dk\,k^3 |\widehat f_\tau(k)|^2 =\frac1{24\pi^2\tau^4}.

    Thus a finer resolution increases the variance as τ−4\tau^{-4}. The Gaussian is a permissible smooth rapidly decreasing sampler for this explicit spectral integral and can be approached by compact smooth samplers. This is a two-dimensional chiral field calculation. It does not justify a four-dimensional null-line stress restriction, where additional transverse smearing can be essential.

    A coherent pulse: mean and noise are different

    Displace the current by the classical profile

    jcl(u)=Ae−u2/(2ℓ2),ℓ>0.j_{\rm cl}(u)=A e^{-u^2/(2\ell^2)}, \qquad \ell>0.

    This defines an algebraic coherent state on the current algebra; Fock-space implementability is not assumed. Its nonzero integrated current makes the displacement one-particle norm infrared divergent, while the sampled observables below remain finite. Its mean stress is jcl2j_{\rm cl}^2. The sampled mean is

    ⟨T(fτ)⟩A=A21+τ2/ℓ2.\langle T(f_\tau)\rangle_A =\frac{A^2}{\sqrt{1+\tau^2/\ell^2}}.

    After centering, the stress has a vacuum quadratic part and a linear part 2jclj2j_{\rm cl}j. Their mixed covariance vanishes because the vacuum has no odd current correlations. Consequently

    Var⁡AT(fτ)=124π2τ4+1π∫0∞dk k∣fτjcl^(k)∣2.\operatorname{Var}_A T(f_\tau) =\frac1{24\pi^2\tau^4} +\frac1\pi\int_0^\infty dk\,k \left|\widehat{f_\tau j_{\rm cl}}(k)\right|^2.

    For b=τ−2+(2ℓ2)−1b=\tau^{-2}+(2\ell^2)^{-1},

    fτjcl^(k)=Aτbe−k2/(4b).\widehat{f_\tau j_{\rm cl}}(k) =\frac{A}{\tau\sqrt b}e^{-k^2/(4b)}.

    The integral is elementary, yielding

    Var⁡AT(fτ)=124π2τ4+A2πτ2.\operatorname{Var}_A T(f_\tau) =\frac1{24\pi^2\tau^4}+\frac{A^2}{\pi\tau^2}.

    For this centered Gaussian family the additional variance is independent of ℓ\ell, even though the mean is not. As the pulse narrows, its spectral support broadens; it is not legitimate to infer variance only from its integrated mean. The ℓ→0\ell\to0 limit is not uniform in the weighted Fourier integral defining the variance.

    For ℓ=τ=1\ell=\tau=1 and A=2A=2 in the corresponding length units, the mean is 2.8284272.828427, the vacuum variance is 0.0042217160.004221716, and the coherent-state variance is 1.2774611.277461. The companion checks the mean by position integration and the variance by spectral integration. It also evaluates the two-current Wick convolution independently, recovering the k3/6k^3/6 pair phase-space factor and the same vacuum coefficient.

    What this says about semiclassical gravity

    Large matter fluctuations do not by themselves give a metric fluctuation: the metric response and the observable's gauge-invariant definition are also needed. A ratio of stress standard deviation to mean is particularly misleading in the vacuum, where its denominator is zero despite the finite smeared variance. The sampling scale, gravitational coupling and retarded response must all enter a semiclassical validity analysis.

    For NN independent identical fields, the summed mean is NN times the single-field mean, and the summed variance is NN times the single-field variance. Where the mean is nonzero, relative fluctuations therefore fall as N−1/2N^{-1/2}. Correlations between fields would change that counting. The semiclassical gravity chapter uses the noise as an input to response, rather than treating it as a metric covariance already computed.

    With a specified metric response, this smeared stress covariance can source a new observable. The Einstein–Langevin calculation propagates a four-dimensional massive trace channel to a smeared curvature covariance. The two-dimensional chiral normalization used here belongs to a different component and dimension.

    Summary

    Stress noise is a centered symmetrized distribution whose positive variance is defined after smearing. The explicit vacuum coefficient scales with resolution, while a coherent pulse adds a separate covariance not determined by its mean alone. The same distinction is needed before interpreting matter noise as gravitational fluctuations.

    Exercises

    1. For NN independent vacuum fields, calculate the variance of their average stress N−1∑iTi(fτ)N^{-1}\sum_iT_i(f_\tau) and of their sum.
    Solution

    Independence removes cross covariances. The sum has variance N/(24π2τ4)N/(24\pi^2\tau^4); the average has variance 1/(24Nπ2τ4)1/(24N\pi^2\tau^4). Both means vanish, so a relative-to-mean ratio is undefined even though the absolute variances and their NN dependence are well defined.

    1. At fixed ℓ\ell and τ\tau, determine the large-AA scaling of the coherent state's relative standard deviation. Does this remove vacuum fluctuations from the state?
    Solution

    The mean is proportional to A2A^2, while the leading variance is A2/(πτ2)A^2/(\pi\tau^2). Thus

    Var⁡AT(fτ)⟨T(fτ)⟩A∼1+τ2/ℓ2π ∣A∣τ.\frac{\sqrt{\operatorname{Var}_A T(f_\tau)}}{ \langle T(f_\tau)\rangle_A} \sim\frac{\sqrt{1+\tau^2/\ell^2}}{\sqrt\pi\,|A|\tau}.

    The relative size falls as ∣A∣−1|A|^{-1}. The state still contains the unchanged vacuum quadratic contribution 1/(24π2τ4)1/(24\pi^2\tau^4); large mean energy makes its relative effect small rather than removing it.

    References

    • B. L. Hu and E. Verdaguer, Stochastic Gravity: Theory and Applications, §§3.1–3.2 for the centered noise, its distributional meaning and semiclassical-validity discussion; §5 for Wick reduction of separated stress correlators.

    Scrollable formula. Use Left and Right arrow keys to reveal hidden content.

    Scrollable table. Use Left and Right arrow keys to reveal hidden columns.

    Scrollable figure. Use Left and Right arrow keys to reveal hidden content.