    Particle Number and Detector Response without an Out Vacuum

    What happens to a detector prediction if two observers assign different occupation numbers to the same expanding universe? Hold the geometry, field state, worldline, clock, coupling and switching function fixed. We will construct two normalized mode choices on one slice. They assign 00 and 0.02250.0225 to the same wave number, while both give the same finite excitation probability.

    Preparation. Use the Klein–Gordon normalization of FLRW modes and the finite-switching detector response. The field is a massless real scalar with conformal curvature coupling in four spacetime dimensions. Set c=ℏ=1c=\hbar=1 and use the mostly-minus metric.

    Prescribe one finite experiment

    Use the expanding conformal patch η>−1/h\eta>-1/h with h>0h>0 and spatial slices R3\mathbb R^3. There is no static late-time region. With a(0)=1a(0)=1,

    ds2=a2(η)(dη2−dx2),a(η)=1+hη,a′′=0.\begin{gathered} ds^2=a^2(\eta)(d\eta^2-d\mathbf x^2),\\ a(\eta)=1+h\eta,\qquad a''=0. \end{gathered}

    Here hh is the constant slope in conformal time. The physical Hubble parameter is a′/a2=h/a2a'/a^2=h/a^2. Choose the conformal vacuum, the transport of the Minkowski vacuum. Its two-point function is Hadamard in the interior of this smooth patch. In the expansion with measure d3k/(2π)3d^3k/(2\pi)^3 and the corresponding (2π)3(2\pi)^3 commutator, write k=∣k∣>0k=|\mathbf k|>0. The normalized positive-frequency modes are

    uk(η,x)=eik⋅x−ikηa(η)2k.u_{\mathbf k}(\eta,\mathbf x)= \frac{e^{i\mathbf k\cdot\mathbf x-ik\eta}}{a(\eta)\sqrt{2k}}.

    A comoving detector at x=0\mathbf x=0 begins in its ground state with proper-time energy gap Ω>0\Omega>0. Choose τ(0)=0\tau(0)=0, so dτ=a dηd\tau=a\,d\eta and τ=η+hη2/2\tau=\eta+h\eta^2/2. Switch it on only for ∣η∣<T|\eta|<T, with 0<hT<10<hT<1. For ∣s∣<1|s|<1 define the smooth bump by

    b(s)=exp⁡(1−11−s2).b(s)=\exp\left(1-\frac{1}{1-s^2}\right).

    Set b(s)=0b(s)=0 for ∣s∣≥1|s|\ge 1.

    The laboratory uses the fixed proper-time function χ(τ)=b(η(τ)/T)\chi(\tau)=b(\eta(\tau)/T). The parameterization by conformal time specifies this one switch; the detector phase still uses its proper clock.

    Two instantaneous choices on the same slice

    At η=0\eta=0 the first assignment uses uku_{\mathbf k}. These are the positive-frequency normalized initial data of the rescaled field aϕa\phi, continued by its exact oscillator equation. Since the prepared state is their vacuum, nA(k)=0n_A(k)=0.

    A different instantaneous construction uses the canonical field ϕ\phi and momentum a2ϕ′a^2\phi'. In this a′′=0a''=0 model the time-slice oscillator Hamiltonian for a mode has kinetic coefficient a−2a^{-2} and spring coefficient a2k2a^2k^2. Its positive-frequency initial condition at a=1a=1 is v′=−ikvv'=-ikv, whereas u′=(−ik−h)uu'=(-ik-h)u. Apply the second prescription around a chosen wave number k∗k_*, leaving the ultraviolet data exactly as in the first choice. Let fk=b((k−k∗)/Δk)f_k=b((k-k_*)/\Delta k) with 0<Δk<k∗0<\Delta k<k_*. Define exact solutions by

    vk(0)=uk(0),vk′(0)=uk′(0)+hfkuk(0).\begin{gathered} v_{\mathbf k}(0)=u_{\mathbf k}(0),\\ v'_{\mathbf k}(0)=u'_{\mathbf k}(0)+hf_ku_{\mathbf k}(0). \end{gathered}

    At k=k∗k=k_* this is the instantaneous Hamiltonian prescription. The real derivative shift preserves the Klein–Gordon product. Compact support away from zero and infinity makes the changes to the two-point function of the associated vacuum smooth. The preparation stays the original conformal vacuum throughout.

    To compare the modes write vk=αkuk+βku−k∗v_{\mathbf k}=\alpha_k u_{\mathbf k}+\beta_k u^*_{-\mathbf k}. At the slice the values give αk+βk=1\alpha_k+\beta_k=1. Matching derivatives gives 2ikβk=hfk2ik\beta_k=hf_k. Hence

    zk=hfk/(2k),αk=1+izk,βk=−izk,∣αk∣2−∣βk∣2=1.\begin{gathered} z_k=hf_k/(2k),\\ \alpha_k=1+iz_k,\qquad\beta_k=-iz_k,\\ |\alpha_k|^2-|\beta_k|^2=1. \end{gathered}

    The second number assignment in the first vacuum is nB(k)=∣βk∣2=zk2n_B(k)=|\beta_k|^2=z_k^2. For hT=0.3hT=0.3, k∗T=1k_*T=1 and Δk T=1/2\Delta k\,T=1/2 it is 0.02250.0225 at the central wave number. This is the occupation coefficient multiplying the continuum momentum delta function. Normalized wave packets average it with their own weights. It has no preferred late-time interpretation on this patch.

    The probability keeps the anomalous correlations

    At leading order the probability is Pg→e=λ2∣μeg∣2F+O(λ4)P_{g\to e}=\lambda^2|\mu_{eg}|^2\mathcal F+O(\lambda^4), where λ\lambda is the coupling and μeg\mu_{eg} the internal matrix element. Inserting the conformal modes into the switched Wightman integral gives

    I±(k)=∫−TTg(η)e∓ikη dη,F=14π2∫0∞dk k∣I+(k)∣2.\begin{gathered} I_\pm(k)=\int_{-T}^{T} g(\eta)e^{\mp ik\eta}\,d\eta,\\ \mathcal F=\frac1{4\pi^2}\int_0^\infty dk\,k|I_+(k)|^2 . \end{gathered}

    Here g(η)=b(η/T)e−iΩτ(η)g(\eta)=b(\eta/T)e^{-i\Omega\tau(\eta)}. The factor a−1a^{-1} in each mode cancels the Jacobian aa from dτd\tau. Angular integration and the mode norm 1/(2k)1/(2k) give k/(4π2)k/(4\pi^2). The response is dimensionless. Smooth compact switching makes I+I_+ decay faster than any inverse power of kk by repeated integration by parts, at fixed gap and duration. This mode-sum form implements the same pullback and smearing as Louko and Satz, §2, Eqs. (2.1)–(2.4).

    In the second basis the two smeared mode factors are

    J+=αI++βI−,J−=β∗I++α∗I−.\begin{gathered} J_+=\alpha I_++\beta I_-,\\ J_-=\beta^* I_++\alpha^* I_- . \end{gathered}

    These are linear changes of the same mode functions. Inverting gives I+=α∗J+−βJ−I_+=\alpha^*J_+-\beta J_-. The fixed-state integrand is therefore ∣α∗J+−βJ−∣2|\alpha^*J_+-\beta J_-|^2. Its cross term is the contribution of the anomalous pair correlation in the new basis. Keeping only the two diagonal occupation terms instead gives ∣α∣2∣J+∣2+∣β∣2∣J−∣2|\alpha|^2|J_+|^2+|\beta|^2|J_-|^2. This evaluates another covariance and changes the physical answer.

    Set ΩT=1\Omega T=1 in the experiment above. Independent conformal-time and proper-time quadratures give F=0.04527377\mathcal F=0.04527377. The second basis reproduces this value pointwise in the outer momentum integral. Dropping its cross term gives 0.045898840.04589884. With the switch still finite but h=0h=0, both mode choices coincide and the inertial vacuum result is 0.045153650.04515365. This nonzero control comes from finite switching. None of these entries is a late-time rate or a temperature.

    Exercises

    1. Is diagonalizing the unscaled Hamiltonian at every wave number an innocuous ultraviolet change? Set fk=1f_k=1 and inspect its number density on the three-dimensional slice. Explain the role of the compact band in the comparison.

    Solution

    The occupation would behave as h2/(4k2)h^2/(4k^2) at large kk. The number-density integral would contain ∫∞dk k2nB(k)∝∫∞dk\int^\infty dk\,k^2n_B(k)\propto\int^\infty dk. Such a tail also modifies the short-distance correlations. Wronskian normalization at each kk alone does not ensure ultraviolet admissibility. The smooth band preserves a nonzero occupation at k∗k_* while keeping all sufficiently high-momentum modes identical to the conformal ones.

    2. Which probability would the vacuum of the second basis give? Decide which of the three expressions ∣I+∣2|I_+|^2, ∣J+∣2|J_+|^2 and ∣α∣2∣J+∣2+∣β∣2∣J−∣2|\alpha|^2|J_+|^2+|\beta|^2|J_-|^2 to integrate if the field preparation is actually changed to the vv vacuum.

    Solution

    In the vv vacuum the vv annihilators annihilate the state. Its Wightman function is the positive-frequency vv mode sum, giving ∣J+∣2|J_+|^2. The conformal vacuum uses ∣I+∣2|I_+|^2 in its own basis and ∣α∗J+−βJ−∣2|\alpha^*J_+-\beta J_-|^2 in the vv basis. The incoherent diagonal sum describes a third choice of two-point function. Selecting a vacuum is a change of input; expanding its fixed two-point function in another pair of solutions is a change of coordinates on the solution space.

    Sources and reproducibility

    Scrollable formula. Use Left and Right arrow keys to reveal hidden content.

    Scrollable table. Use Left and Right arrow keys to reveal hidden columns.

    Scrollable figure. Use Left and Right arrow keys to reveal hidden content.