- Home
- Library
- Quantum Fields in Curved Spacetime
- What a Local Detector Measures
- Switching, Smearing, and Detector Regularization
Switching, Smearing, and Detector Regularization
A measurement with shorter duration probes higher frequencies. A detector with nonzero size suppresses high spatial momenta. These are different controls, and a concrete Gaussian experiment shows that their limits need not commute.
Preparation: the inertial response. Keep the four-dimensional massless Minkowski vacuum and positive gap . We vary a physical detector profile, not an unremoved prescription.
First define the distributional pairing
For a Hadamard state and smooth compact switching, the timelike pullback of is a distribution paired with the two time test functions. One integrates its regulated boundary value before removing the regulator. A discontinuous switch is not covered by this statement: its Fourier tail can make the total point-detector probability diverge.
In the inertial massless case,
A sharp rectangular switch has , producing a logarithmic ultraviolet divergence in this integral. A smooth switch avoids this tail. A sharp-switch rate, when defined through a special limiting prescription, is a different quantity from this divergent total probability. Louko and Satz, §2–§4 make this distinction explicitly.
Give an inertial detector a spatial profile
In its rest frame replace the point field by
The profile integrates to one and has transform . It is a smooth, spatially noncompact model of resolution . Smearing both fields therefore multiplies the positive momentum measure by .
For the temporal switch , the finite response becomes
It is positive and decreases monotonically with at fixed . This is an exact statement for this profile and state, not a general ordering theorem for every detector.
Complete the square by setting
The result is
Here may have either sign. The scaled error function avoids separately multiplying a large exponential by a tiny complementary error function; at extremely large positive its remaining subtraction is best handled by an asymptotic expansion or the positive integral.
Vary duration and size independently
At , direct quadrature and the closed expression give:
| Point | |||
|---|---|---|---|
The table holds the state and gap fixed. Short switches depend strongly on size because their broad frequency band reaches momenta removed by the spatial profile. Increasing and decreasing are separate refinements, not two names for the same regulator.
At fixed , the difference from the point result is:
The approximately factor-four improvement on halving follows from expanding . More directly, supplies the bound
This proves point-limit convergence at every fixed positive , rather than inferring it from one small size.
Two short-time limits answer different questions
Remove the distributional regulator at fixed first. For the point detector,
The switch becomes narrow at fixed peak height but excites an unbounded range of point-field frequencies. Setting the switch identically to zero would not be this singular limiting operation.
For any fixed , dominated convergence instead gives
For , the exact response at is , compared with the leading value . At they are and . Therefore
Neither limit is a statement about particles already present in the vacuum.
Extending the apparatus to acceleration
For an accelerated detector one must specify the simultaneity convention and profile transport. A common construction uses Fermi–Walker spatial vectors and couples to integrated against a profile. Its support must lie in the domain where this apparatus description is meaningful. A small compact profile compared with the acceleration and curvature scales is different from a Gaussian extending through an acceleration horizon.
Louko and Satz, §2, equations (2.12)–(2.16), and §4 derive controlled zero-size results under specified profile hypotheses. Finite size remains physical input.
Summary
Smooth switching defines a temporal bandwidth; spatial smearing defines a different resolution. Their independent variations give a convergent point limit at fixed smooth duration, but opposite orders of the short-time and point limits give different answers. The exact positive integral makes these statements testable.
Exercises
- Take with fixed and let at fixed gap. Find the limit.
Solution
Now and . The bracket and exponential tend to one, giving . A continuum of answers interpolates between the fixed-ratio protocols. The physical scaling of the apparatus must therefore be stated, even when every finite- integral is well defined.
- Show that spatial smearing does not create an inertial stationary excitation rate in vacuum.
Solution
The smeared spectral rate is
Its support remains on negative gap. Thus the eternal excitation rate is zero, while spontaneous decay is suppressed by the profile at the emitted momentum. A finite switch convolves this same spectrum and can still give a positive excitation response.
References
- J. Louko and A. Satz, How Often Does the Unruh–DeWitt Detector Click? Regularisation by a Spatial Profile, §2, equations (2.12)–(2.16), and §4, for spatial transport and the scope of zero-size limits.
- J. Louko and A. Satz, Transition Rate of the Unruh–DeWitt Detector in Curved Spacetime, §2–§4, for distributional pairing and the sharp-switch distinction.
- The independent size/duration sweep and closed-form checks are retained in
examples/curved-spacetime/detectors-unruh/.
Scrollable formula. Use Left and Right arrow keys to reveal hidden content.
Scrollable table. Use Left and Right arrow keys to reveal hidden columns.
Scrollable figure. Use Left and Right arrow keys to reveal hidden content.