Skip to content
QFT.org

Search QFT.org

Enter a word or phrase.

    You can also browse the main navigation and chapter contents.

    Units and Dimensions

    In natural units, ℏ=c=kB=1\hbar=c=k_{\rm B}=1, the action is dimensionless and energy supplies one common unit:

    [E]=[m]=[T]=1,[x]=[t]=−1,[L]=d.[E]=[m]=[T]=1,\qquad [x]=[t]=-1,\qquad [\mathcal L]=d.

    Here brackets denote mass dimension, and dd counts spacetime dimensions. This convention compares units; it does not set a material's Fermi velocity, sound speed or nonrelativistic mass to one.

    Engineering dimensions from kinetic terms

    For canonically normalized relativistic fields, the kinetic action fixes

    QuantityMass dimension
    Real scalar ϕ\phi(d−2)/2(d-2)/2
    Dirac or Weyl field ψ\psi(d−1)/2(d-1)/2
    Canonical gauge potential AμA_\mu(d−2)/2(d-2)/2
    Gauge coupling gg in Dμ=∂μ−igAμD_\mu=\partial_\mu-igA_\mu(4−d)/2(4-d)/2
    Field strength FμνF_{\mu\nu}d/2d/2
    Scalar source JJ in JϕJ\phi(d+2)/2(d+2)/2
    Quartic coupling λ\lambda in λϕ4/4!\lambda\phi^4/4!4−d4-d
    Yukawa coupling yy in yϕψˉψy\phi\bar\psi\psi(4−d)/2(4-d)/2

    For example, 2+2[ϕ]=d2+2[\phi]=d follows from (∂ϕ)2/2(\partial\phi)^2/2, while 1+2[ψ]=d1+2[\psi]=d follows from iψˉγμ∂μψi\bar\psi\gamma^\mu\partial_\mu\psi. If the connection is instead A=gA\mathcal A=gA, then [A]=1[\mathcal A]=1 and the kinetic coefficient carries 1/g21/g^2. Its dimension should not be copied from the canonical AA row.

    For a local operator of engineering dimension Δ0\Delta_0, the coefficient of O\mathcal O in a Lagrangian has dimension d−Δ0d-\Delta_0. At a nontrivial fixed point the scaling dimension can differ from Δ0\Delta_0 by an anomalous part. In nonrelativistic scaling with dynamical exponent zz, time and space scale differently; the table is not the corresponding power-counting rule. See interactions and dimensions and EFT power counting.

    Restore ordinary units

    The following conversion factors follow from the exact SI definitions of hh, cc, the elementary charge and kBk_{\rm B}, as tabulated in the NIST CODATA 2022 wall chart:

    ScaleValue
    ℏc\hbar c0.197326980459…0.197326980459\ldots GeV fm
    ℏ\hbar6.582119569…6.582119569\ldots ×10−25\times10^{-25} GeV s
    kBk_{\rm B}8.617333262…8.617333262\ldots ×10−14\times10^{-14} GeV/K

    Hence 1 GeV−11\,\mathrm{GeV}^{-1} as a length is 0.197326980459…0.197326980459\ldots fm. As a time it is 6.582119569…×10−256.582119569\ldots\times10^{-25} s. For an area, 1 GeV−21\,\mathrm{GeV}^{-2} is 0.389379372…0.389379372\ldots mb.

    A femtometer is 10−15 m10^{-15}\,\mathrm m; a millibarn is 10−31 m210^{-31}\,\mathrm m^2. The area conversion squares ℏc\hbar c, not ℏ\hbar alone. An ellipsis marks omitted digits, not an experimental uncertainty. Measured dimensionless quantities such as the fine-structure constant still have uncertainty.

    Three quick checks

    A mass quoted as mc2=2 GeVmc^2=2\,\mathrm{GeV} has reduced Compton wavelength

    ℓC=ℏcmc2=0.09866349… fm.\ell_C=\frac{\hbar c}{mc^2}=0.09866349\ldots\,\mathrm{fm}.

    The ordinary Compton wavelength h/(mc)h/(mc) is larger by 2π2\pi. Naming the wavelength prevents a hidden Fourier-normalization error.

    For an exponential decay whose energy width is Γ=10−12 GeV\Gamma=10^{-12}\,\mathrm{GeV},

    τ=ℏΓ=6.582119569…×10−13 s.\tau=\frac{\hbar}{\Gamma}=6.582119569\ldots\times10^{-13}\,\mathrm s.

    This uses the probability lifetime: an amplitude behaving as e−Γt/(2ℏ)e^{-\Gamma t/(2\hbar)} has probability e−Γt/ℏe^{-\Gamma t/\hbar}.

    Finally, in four dimensions a Fermi coefficient has [GF]=−2[G_F]=-2. A leading three-body weak decay width proportional to GF2m5G_F^2m^5 has dimension one, as required. A proposed expression proportional to GF2m3G_F^2m^3 would need an additional dimensionful factor. Dimensional agreement is necessary, but cannot determine the numerical phase-space coefficient or establish the approximation.

    Convert a cross section into an event count

    A fiducial cross section σ\sigma and integrated luminosity Lint\mathcal L_{\rm int} predict N=LintσN=\mathcal L_{\rm int}\sigma events in that fiducial region before detector losses. Since 1 pb=103 fb1\,\mathrm{pb}=10^3\,\mathrm{fb}, a 2 pb2\,\mathrm{pb} signal in 3 fb−13\,\mathrm{fb}^{-1} gives 6,0006{,}000 events. If the overall reconstruction efficiency within the region is 0.400.40, the expected selected signal is 2,4002{,}400. A cross section that already includes the fiducial cuts should not be multiplied by their acceptance again. Invariant flux and cross section.

    References

    • NIST. CODATA Recommended Values of the Fundamental Physical Constants: 2022, SP 961, May 2024, constants and conversion definitions.
    • QFT.org. Conventions, §§3.2 and 8.3; interactions and dimensions for the kinetic-term derivation and relevance of interactions.

    Scrollable formula. Use Left and Right arrow keys to reveal hidden content.

    Scrollable table. Use Left and Right arrow keys to reveal hidden columns.

    Scrollable figure. Use Left and Right arrow keys to reveal hidden content.