Skip to content
QFT.org

Search QFT.org

Enter a word or phrase.

    You can also browse the main navigation and chapter contents.

    Normalized Distributions and Singular Covariance

    For a normalized spectrum with bin densities hih_i and widths wiw_i, first check ∑iwihi=1\sum_i w_i h_i=1. The same sum must hold for the prediction. The covariance ChC_h of a spectrum normalized in every realization obeys Chw=0C_h w=0. If normalization is the only exact constraint, compare data and prediction in one fewer bin. Remove the same bin from the residual vector and the matching row and column from the covariance. The choice of bin gives the same quadratic discrepancy.

    Convert densities and propagate normalization

    For bin-integrated yields yiy_i and nonzero total Y=∑jyjY=\sum_j y_j in the quoted range, define the fractions fi=yi/Yf_i=y_i/Y and densities hi=fi/wih_i=f_i/w_i. If a theory predicts a differential density, integrate it between the bin edges before comparing fractions. A density evaluated at a bin center can miss a rapidly varying threshold.

    For a covariance VV on the original yields, first-order propagation gives

    Jij=δij−fiY,Cf≃JVJT,(Ch)ij=(Cf)ijwiwj.J_{ij}=\frac{\delta_{ij}-f_i}{Y},\qquad C_f\simeq J V J^{\mathsf T}, \qquad (C_h)_{ij}=\frac{(C_f)_{ij}}{w_iw_j}.

    Every column of JJ sums to zero. A common multiplicative shift has direction yy and drops out because Jy=0Jy=0. If the experiment supplies a covariance already computed for the normalized distribution, use it in its published coordinates. Normalization to an independently measured cross section, or a table covering only part of the normalization range, need not impose this exact constraint on the selected bins.

    Three bins, two independent residuals

    Take three bins of widths 1,2,41,2,4 GeV and exactly N=100N=100 independent events. A candidate model assigns probabilities p=(0.20,0.30,0.50)p=(0.20,0.30,0.50). Suppose the observed counts are (25,25,50)(25,25,50). The measured fractions are (0.25,0.25,0.50)(0.25,0.25,0.50), while the measured densities are (0.25,0.125,0.125)(0.25,0.125,0.125) in GeV−1\mathrm{GeV}^{-1}. Multiplying the latter by the widths recovers the fractions.

    For this fixed-count model the fraction covariance is exactly

    (Cf)ij=piδij−pipjN.(C_f)_{ij}=\frac{p_i\delta_{ij}-p_ip_j}{N}.

    For a single event, the product of two different bin indicators is zero. Subtracting the product of their means gives the negative off-diagonal terms. Averaging NN independent indicators divides their covariance by NN.

    The residual r=f−p=(0.05,−0.05,0)r=f-p=(0.05,-0.05,0) sums to zero. Dropping the third bin leaves

    Csub=1100(0.16−0.06−0.060.21),χshape2=rsubTCsub−1rsub=2512.C_{\rm sub}=\frac{1}{100} \begin{pmatrix}0.16&-0.06\\-0.06&0.21\end{pmatrix}, \qquad \chi^2_{\rm shape}=r_{\rm sub}^{\mathsf T}C_{\rm sub}^{-1}r_{\rm sub} =\frac{25}{12}.

    Dropping either other bin gives the same value. In this multinomial example one can also check it from N∑iri2/piN\sum_i r_i^2/p_i. With a fixed model and sufficiently large expected counts, the reference chi-square distribution has two degrees of freedom. Sparse counts call for a multinomial likelihood or a sampling calculation. An unfolded spectrum generally needs the experiment's full covariance, including its treatment of systematics.

    What the discarded bin can tell you

    The removed residual is fixed by the others through the unit-sum constraint. For densities it obeys rk=−∑i≠kwiri/wkr_k=-\sum_{i\ne k}w_i r_i/w_k. The comparison therefore retains every independent shape difference. It loses sensitivity to a common rescaling of the original spectrum. To test the inclusive rate too, obtain the measured normalization and its correlations with the shape.

    For an actual application, CMS defines the normalized top-pair cross section and constructs the reduced covariance from its unfolding and systematic uncertainties. CMS Collaboration, Eqs. (1)–(3). For a covariance with full rank, the two-bin comparison uses both residuals directly.

    Scrollable formula. Use Left and Right arrow keys to reveal hidden content.

    Scrollable table. Use Left and Right arrow keys to reveal hidden columns.