Skip to content
QFT.org

Search QFT.org

Enter a word or phrase.

    You can also browse the main navigation and chapter contents.

    Particle Data and Physical Constants

    A particle parameter is specified by the quantity, its definition, units, uncertainty and source edition. For example, a running quark mass m‾q(μ)\overline m_q(\mu) in MS‾\overline{\mathrm{MS}} is not the same object as a pole-mass parameter. A numerical value without its definition can be unusable even when every digit was copied correctly.

    The Particle Data Group supplies reviewed particle properties and topical reviews; NIST CODATA supplies fundamental physical constants. Use the current source record for a new numerical analysis, and retain the edition actually used so a later update does not silently change the calculation.

    Constants: exact definitions versus measurements

    The speed of light cc, Planck constant hh, elementary charge magnitude ee and Boltzmann constant kBk_{\rm B} have exact SI values.

    SymbolExact SI value
    cc299792458 m s−1299792458\,\mathrm{m\,s^{-1}}
    hh6.626070156.62607015 ×10−34\times10^{-34} J s
    ee1.6021766341.602176634 ×10−19\times10^{-19} C
    kBk_{\rm B}1.3806491.380649 ×10−23\times10^{-23} J/K

    Consequently ℏ=h/(2π)\hbar=h/(2\pi) and the GeV-to-joule conversion are exact definitions, although their decimal expansions may be truncated. In contrast, the CODATA 2022 adjusted low-energy fine-structure constant has

    α−1=137.035999177(21).\alpha^{-1}=137.035999177(21).

    The parentheses denote standard uncertainty in the final digits: here 0.0000000210.000000021. This is the low-energy constant, not a substitute for a running high-energy coupling. See the NIST 2022 table and unit conversions.

    What to record for a particle input

    InputDefinition to retain
    MassParticle identity; pole, line-shape or running-mass convention; scale and scheme when relevant.
    Width or lifetimeTotal versus partial; exponential-lifetime convention; any branching fraction used.
    CouplingNormalization, renormalization scale, active flavors, scheme and perturbative order.
    Mixing parameterMatrix parameterization, phase convention, mass ordering and fit assumptions.
    LimitConfidence or credibility level, one- or two-sided construction and model assumptions.
    Fit resultCorrelations, common nuisance parameters and whether the value was a direct measurement or constrained fit.

    PDG listings distinguish individual measurements from summary information. A recommended summary, fit output and the most recent individual measurement can answer different questions. Read the notes associated with the quantity rather than treating a displayed average as a definition of the theory.

    The PDG API documentation describes edition and release metadata and stable quantity identifiers. These identifiers refer to PDG records; they are not automatically interchangeable with Monte Carlo particle-number codes. Programmatic retrieval should preserve units, qualifiers and metadata as well as the central value.

    Propagate the observable's inputs

    For a resonance, first establish which mass and width the experiment fitted. As an example, suppose its line-shape denominator is s−M2+is Γ/Ms-M^2+i s\,\Gamma/M. With a=Γ/Ma=\Gamma/M the zero is s⋆=M2/(1+ia)s_\star=M^2/(1+ia). A calculation using s⋆=μ2−iμγs_\star=\mu^2-i\mu\gamma therefore needs

    μ=M1+a2,γ=Γ1+a2.\mu=\frac{M}{\sqrt{1+a^2}},\qquad \gamma=\frac{\Gamma}{\sqrt{1+a^2}}.

    If the reported MM and Γ\Gamma are correlated, propagate their joint covariance. To first order in their uncertainties, at any aa in this parametrization,

    (dμdγ)=1(1+a2)3/2(1+2a2−aa31)(dMdΓ).\begin{pmatrix}d\mu\\d\gamma\end{pmatrix} =\frac1{(1+a^2)^{3/2}} \begin{pmatrix}1+2a^2&-a\\a^3&1\end{pmatrix} \begin{pmatrix}dM\\d\Gamma\end{pmatrix}.

    For example, increasing the fitted width at fixed MM lowers μ\mu, with slope −a/(1+a2)3/2-a/(1+a^2)^{3/2}. Use this matrix on both sides of the original covariance, Cpole=JCfitJTC_{\rm pole}=J C_{\rm fit}J^{\mathsf T}. A convention based on s⋆=ME−iΓE/2\sqrt{s_\star}=M_E-i\Gamma_E/2 uses a different transformation. Pole coordinates, residues and line shapes · PDG electroweak review, §10.2.4.

    Width from a lifetime

    For a narrow isolated exponential decay, Γ=ℏ/τ\Gamma=\hbar/\tau. A small standard uncertainty propagates as

    σΓ=ℏτ2στ,σΓΓ=σττ.\sigma_\Gamma=\frac{\hbar}{\tau^2}\sigma_\tau, \qquad \frac{\sigma_\Gamma}{\Gamma}=\frac{\sigma_\tau}{\tau}.

    This first-order rule does not preserve the shape of a large asymmetric lifetime interval; transform its endpoints or the likelihood instead.

    For a vector of correlated inputs xix_i and a smooth prediction f(x)f(x),

    σf2≃∑ij∂f∂xiCij∂f∂xj,Cij=Cov⁡(xi,xj).\sigma_f^2\simeq\sum_{ij}\frac{\partial f}{\partial x_i} C_{ij}\frac{\partial f}{\partial x_j}, \qquad C_{ij}=\operatorname{Cov}(x_i,x_j).

    For f=x−yf=x-y, this is σx2+σy2−2Cxy\sigma_x^2+\sigma_y^2-2C_{xy}. Equal fully correlated additive uncertainties cancel in the difference, whereas independent ones add in quadrature. Treating common calibration errors as independent can therefore change the answer qualitatively. A covariance matrix alone may be inadequate for nonlinear predictions, non-Gaussian tails or limits.

    For an application, compare the definitions in electroweak inputs, then use data-source guidance to retain the relevant record and covariance.

    References

    Scrollable formula. Use Left and Right arrow keys to reveal hidden content.

    Scrollable table. Use Left and Right arrow keys to reveal hidden columns.

    Scrollable figure. Use Left and Right arrow keys to reveal hidden content.