An infrared-finite answer is meaningful only after specifying what is prepared and what is measured. Summing over unresolved radiation, imposing a bound on its total energy, and projecting onto a coherent cloud are three different operations. They can agree in a controlled example without being interchangeable definitions of scattering.
We will compare them exactly for a prescribed linear boson source. The source has infinitely many soft emissions in its cutoff limit, but finite total radiated energy. Its total-energy distribution can be calculated in closed form and checked by deterministic finite-cutoff bounds.
Preparation: Infraparticles and charged representations fixes the radial boson model and its spectral measure. Dressed asymptotic states explains the leading soft-current displacement in massive Abelian scattering. Here is a model parameter, not an electromagnetic coupling or a universal soft exponent.
An exactly defined transition at finite cutoff
Work on with . Let
This is the positive profile of the preceding article. Define the soft transition operator by
It is an exact scattering map for a prescribed linear source, rather than an approximation to an unspecified hard scattering operator. For example, choose a real smooth switching function whose derivative has compact support, with and . The interaction-picture pulse
is self-adjoint. Its values at different times commute, so its time-ordered exponential is and . More general prescribed linear sources have a scalar commutator and add a calculable phase. None of the probabilities below depends on that phase.
Starting from the free vacuum, the normalized outgoing state is the coherent state . Its mean particle number is
while its mean free energy is . The cutoff vectors have no Fock norm limit, as proved in the preceding article. In particular, cannot converge strongly on the original Fock space: its action on the vacuum already fails to converge, even after adjusting scalar phases.
Coherent emission gives a Poisson energy measure
Introduce the finite measure
The -particle component of the coherent vector has squared norm . More precisely, its unordered energy distribution is
Thus emitted energies form a Poisson point process with intensity . Disjoint energy bands have independent Poisson counts. This statement follows from the coherent Fock expansion, including its factor; it does not require a Monte Carlo model.
Let
be total radiated free energy. Its Laplace transform is
Equivalently, this is the coherent expectation of . In the present model,
At fixed , the factor cancels the infrared singularity. Sending gives
This is the Gamma distribution
It is the same density that appeared as the vacuum spectral measure of the shifted source Hamiltonian. The equality follows from the displacement identities; the observable is now the free energy in the outgoing coherent state.
The limiting process has infinite total point intensity, since , but finite expected energy,
One may couple all cutoffs using the same Poisson random measure. Then increases to a finite random variable almost surely and in mean. Infinite emission count and finite total energy are compatible.
First measurement: no individually resolved boson
Fix a detector resolution , and remove the infrared cutoff with . The one-particle space splits into energies below and above , and Fock space factorizes:
The detector accepts any state in the unresolved factor but demands the vacuum in the resolved factor. Its acceptance projector is
Taking the trace over all unresolved radiation gives
It is already independent of once . The same result follows by summing all unresolved multiplicities:
The exponential suppression and the unresolved sum are parts of one normalized probability. In a perturbative QED interpretation they correspond to the familiar cancellation between exclusive suppression and unresolved emissions, but the exact result here concerns the specified linear source.
Second measurement: a total-energy bound
Now accept only states with . The measurement is the spectral projector , whose finite-cutoff probability is
The integral is one: its empty energy sum is zero, and it contributes the vacuum probability . For finite , terms with have zero integration volume. The sum constraint couples the emitted energies, so it cannot be replaced by independent restrictions .
At fixed positive resolution, the limiting Gamma law gives
Every event passing the total-energy cut passes the individual-boson veto, but the converse fails: two bosons of energy each pass the veto and fail the total-energy cut. Correspondingly,
The strict inequality follows because there is positive probability for two emissions in a sufficiently small band around and no other emissions above a lower fixed threshold.
The distinction persists in the small-resolution coefficient. After taking at fixed , put . Then
The two measurements have the same leading logarithmic exponent and different finite coefficients.
For , the limiting probabilities are:
| Individual veto | Total-energy cut | |
|---|---|---|
Control the cutoff limit
The coupling of cutoffs supplies a useful error estimate. Write
For any , positivity and Markov's inequality imply
where is the limiting Gamma cumulative distribution and the finite-cutoff one. Choosing, for example, proves convergence at each fixed . This proof controls the limit independently of numerical agreement.
A deterministic check can bracket without sampling emissions. Round every jump energy upward or downward to multiples of a mesh width . Upward rounding gives a lower probability for the total-energy cut, and downward rounding gives an upper probability. If is the intensity assigned to positive lattice energy , the compound-Poisson coefficients obey
This follows by differentiating the generating function . A zero-energy bin created by downward rounding must be omitted from the exponent determining ; those emissions do not change the rounded energy.
At and , using equal energy cells gives the following rounded intervals. Endpoints shown here are rounded outward:
| Lower probability | Upper probability | |
|---|---|---|
Refining from to to cells tightens each rounding bracket. The continuum value is . The rounding inequalities are analytic; the displayed evaluation uses floating-point arithmetic, not certified interval arithmetic. A fixed mesh also becomes less efficient when the mean number of very soft emissions grows, which is why cutoff and mesh errors must be tracked separately.
Third measurement: a matched dressed projection
Project the outgoing state onto the full coherent cloud . At every finite cutoff,
This is a different measurement from either energy cut. Its probability is one because the source produces precisely the selected cloud, not because the source emits no radiation. Nor does the limit of these probabilities define a projection onto a nonexistent limiting Fock vector.
For a real mismatch parameter , choosing the target gives
Only the exactly matched leading profile avoids the divergent norm in this family. More generally, the incoming and outgoing dressings enter through the finite-cutoff difference
Here the ket labels denote coherent states. The displacement must be combined before taking the vacuum expectation; multiplying an isolated cloud-overlap factor into an already suppressed probability would not implement matching.
There is an exact equality with the first measurement if the target is chosen more selectively:
The projection onto this vector has probability
The unresolved factor is the same pure coherent state on both sides; its overlap is one. This is the precise equality established by the model. The two projectors are different operators, and their probabilities need not agree on another outgoing state. Neither equals the total-energy measurement.
The broader distinction between a reduced-state trace and a dressed-state preparation is discussed in Carney et al., introduction and §II, equations (11)–(12). Their QED calculation has angular profiles, charged momenta and a different oscillator measure; no QED exponent is imported into our radial model.
Which limit and which scattering problem?
The meaningful detector procedure here is
followed, if desired, by a separate small-resolution limit. Every fixed finite-particle sector has vanishing probability, yet summing all allowed unresolved multiplicities gives a nonzero result at fixed resolution. This is a nonuniform limit in particle number.
The coherent cutoff states also define limiting expectations on the energy-band Weyl algebra described in the preceding article. That algebraic state limit is not a Fock norm limit. An inclusive probability, meanwhile, is a limit of specified spectral or counting measurements, not an assertion that the outgoing density operators converge in trace norm.
For electromagnetic scattering, one must additionally control recoil, the Coulomb field and phases, the hard process, the allowed asymptotic representations and the approximation being used. The massive QED inclusive calculation includes a specified regulator, virtual correction and finite resolution terms that are absent here. An exact soft-source identity is useful evidence about a mechanism; it is not asymptotic completeness or a full charged QED scattering construction.
Summary
The linear source produces a coherent Poisson energy process. At fixed detector resolution, removing the infrared cutoff yields a finite individual-boson veto and a different finite total-energy probability. Their common power law does not make the measurements equal.
A projection onto the matched full cloud has probability one. A projection onto the matched unresolved cloud with no resolved radiation agrees exactly with the individual veto for this factorized outgoing state. The calculation specifies both the equality and its limitations.
Exercises
1. Check the finite coefficient at
Find the total-energy probability at and compare its small-resolution ratio to the individual-boson veto. Does equality of their logarithmic exponents imply equality of probabilities?
Solution
The limiting energy density is exponential, so
Writing , this is . Meanwhile,
The ratio tends to . Both logarithms have leading term , but their finite difference remains measurable. The total-energy event is the stricter condition.
2. How fast must a particle-number truncation grow?
The total count is Poisson with mean . Suppose a calculation retains at most bosons, with . Determine the limiting retained probability when or .
Solution
For a Poisson count , the variance is . Chebyshev's inequality gives
If , choose with ; eventually the retained event lies in the lower deviation event, so its probability tends to zero. If , the omitted event lies in an upper deviation event, so the retained probability tends to one.
The boundary case needs more information about the difference , typically on the scale . Keeping a fixed number of emissions cannot approximate this infrared limit; a useful truncation must grow at least on its logarithmic mean-number scale.
3. Break the trace–projection equality
At finite , let be a normalized one-boson mode in the unresolved band. Replace the outgoing state by
Compare the individual-boson veto probability with projection onto the matched unresolved cloud and resolved vacuum.
Solution
The state is normalized because is unitary and . Its resolved factor is vacuum, so the inclusive veto accepts it with probability one. The dressed projection has unresolved amplitude
Its probability is zero. The equality in the main example depended on the actual unresolved state being the selected coherent state; it was not an identity between the measurement operators.
4. A joint cutoff limit changes the coefficient
Instead of removing first, let with fixed , and send . Find the total-energy acceptance probability and compare its leading coefficient with the sequential limit.
Solution
Every emitted boson has energy above , so the only accepted event has no emissions. Thus
The individual-boson veto is the same event along this path. Their ratio is one. In the sequential limit, the total-energy coefficient is and the ratio to the individual veto is .
Both procedures can end at zero probability, but their resolved asymptotics and even their comparison ratio differ. Specifying only the final value zero would hide the nonuniform cutoff dependence.
References
- D. Carney, L. Chaurette, D. Neuenfeld and G. W. Semenoff, “Dressed Infrared Quantum Information,” arXiv:1710.02531v1, introduction, §I, equations (1)–(5), and §II, equations (11)–(12) and the discussion of individual versus total photon-energy restrictions. The finite-cutoff coherent states used here have unit norm; their limit is analyzed on a specified algebra.