Extracting CFT Data from Finite Systems
An energy spectrum on a sphere can reveal scaling dimensions. It does not determine OPE coefficients: those require normalized matrix elements of local operators. A free scalar provides a controlled example in which both extractions can be compared with exact flat-space correlators.
We use a conformally coupled scalar in three spacetime dimensions on . Its lowest oscillator gives the primary states of and . A finite discretization then recovers their dimensions and the coefficient , with separate spacing and cutoff checks.
Preparation: The cylinder map, the state–operator map, and free-field normalization. The Hamiltonian uses Lorentzian cylinder time; its metric is , consistent with the mostly-minus convention. Euclidean evolution is used when reading matrix elements from correlators.
What a spherical spectrum measures
For a CFT coupled conformally to the cylinder background,
Thus a primary of dimension has gap , and its nonzero level- descendants have gaps . Subtracting the vacuum energy is necessary: the conformal map fixes these gaps, while an absolute vacuum energy requires a background counterterm and anomaly convention. The map and its normalized-correlator interpretation are derived in Simmons-Duffin, §6.4, Eqs. (90)–(94).
A microscopic Hamiltonian may instead have an effective velocity , giving gaps . Energy ratios determine dimension ratios until is calibrated. Angular momentum, internal symmetry, and the descendant spacing help identify the states. A level near an integer is not sufficient to label a primary: it may be a descendant or a multiparticle state.
For unit-normalized scalar primaries, the state–operator map also gives
To derive this, place the operator producing the ket at the flat origin and the conjugate producing the bra at infinity. Before radius normalization, the scalar three-point function on is . The normalized ket and bra on supply the factor , leaving (2). Rotational invariance makes the answer independent of for scalar states. Spinning states instead require angular projections and tensor structures.
Curvature fixes the free scalar Hamiltonian
On the Euclidean cylinder, the canonical scalar in has conformal coupling and scalar curvature . Continue its positive-frequency oscillators to Lorentzian time. With real unit-sphere harmonics normalized by ,
where
The factor in (3) comes from the oscillator mass in the sphere action. After subtracting the vacuum energy,
The one-particle spectrum has dimension and its traceless derivatives: the mode with angular momentum has gap and multiplicity . The free equation removes trace descendants. This agrees with the independent flat-space representation counting and cylinder two-point expansion in Radial Time and Cylinder Energies.
Many-body states must also be included. If counts twice the dimension, their generating function is
For example, at dimension there are the three first derivatives of and the scalar primary . They share an energy but not an angular-momentum representation. At dimension two, and the three first derivatives of similarly give four states. A spectral table without symmetry labels would merge distinct conformal families.
Extract a three-point coefficient from two oscillator states
The unit flat-space scalar is . Since , its lowest-mode contribution at cylinder time zero is
The normalized primary states are
Their gaps are and . Normal ordering is with respect to the cylinder vacuum, chosen consistently with Weyl transport of these free operators. Between states exciting only the lowest mode, all other modes in the local quadratic operator give zero after the vacuum subtraction. Therefore
for the matrix elements of interest. The arrow restricts these matrix elements; it is not an equality of the full local field with its zero mode.
Equation (9) gives
Combining the first line with (2) recovers , independently of the normalized Wick contractions. The flat-space example there is four-dimensional. Here the three-dimensional free scalar changes the primary dimensions to and , while the normalized pair counting is the same. The second line verifies unit normalization of the operator creating . A gap alone could not supply either matrix element.
There is a useful way to remove a detector normalization and identity contamination simultaneously. If a measured scalar operator has the form within the relevant sector, then
The phase of is fixed by requiring its creation amplitude to be positive. Without that phase choice, the corresponding sign of the OPE coefficient is conventional. Higher-operator contamination would add corrections rather than cancel in (11).
A finite discretization that does not insert the answer
To obtain numerical states independently, represent the lowest oscillator on its dimensionless coordinate :
Discretize at spacing , impose Dirichlet endpoints, and use the centered second derivative. On the interior grid,
The lowest three eigenvectors approximate , , and . Matrix elements use the diagonal operator and the normalized numerical eigenvectors. At finite resolution, subtract the computed vacuum expectation of rather than imposing its continuum value . This enforces the stated vacuum normal-ordering convention without forcing the excited-state matrix element.
At , the results are:
| Ratio (11) | |||
|---|---|---|---|
| Continuum |
Halving the spacing reduces the individual gap and matrix-element errors by approximately four, as expected for a second-order stencil. The direct dimensionless matrix element at the finest spacing is ; it is not replaced by the continuum result in forming the table.
The box-size check is separate. At , the direct matrix element is for , for , and for . Enlarging from to changes it by about , much less than its remaining spacing error. Repeating at leaves the dimensionless gaps and matrix elements unchanged to the retained numerical accuracy. Thus a small box, a coarse grid, and a wrong radius factor are tested separately.
The retained companion, examples/cft/higher-dimensional-cft/finite_system_checks.py, uses a real symmetric tridiagonal eigensolver and records the spacing, box, and radius results. It also counts the Fock multiplicities in (6). No interacting lattice data are being inferred from this calculation.
The angular truncation has a special simplification here: every cutoff retaining gives these same selected matrix elements because the remaining oscillators are free and unexcited. This is not a statement that one angular mode reproduces the full spectrum or a local correlator at arbitrarily small separation.
What changes in an interacting finite system?
The sphere Hamiltonian must be coupled to the correct background before (1) can be used. Dropping gives . The lowest mode is then a free particle on a noncompact field coordinate, with no normalizable constant ground-state wavefunction. Refining the numerical grid cannot turn this wrong Hamiltonian into the conformal oscillator.
In a regulated interacting system, relevant perturbations must be tuned, the effective velocity calibrated, and symmetry sectors identified. A leading irrelevant operator of dimension typically gives corrections of the form
where is a microscopic length and the coefficients depend on the regulator. Several irrelevant operators, logarithms from marginal couplings, or a distinct truncation scale may require a more general fit. Increasing and increasing an energy or basis cutoff are different tests.
Local lattice operators also mix with the identity, descendants, and higher primaries of the same symmetries. Subtractions and two-point normalization must precede an OPE extraction. Curvature-dependent operator terms and stress-tensor improvements are part of specifying the continuum observable; subtracting a vacuum energy cannot compensate for a missing curvature mass. Equation (11) illustrates one solvable subtraction, not a general removal of all operator mixing.
Summary
A conformal sphere spectrum gives excitation dimensions after the radius and velocity are fixed. Normalized matrix elements additionally give OPE data. The three-dimensional free scalar recovers , , and both analytically and from a discretized oscillator. Separate spacing, box, and radius checks distinguish controlled extraction from an accidental spectral ratio.
Exercises
1. Remove an identity admixture
Suppose normalized low states give , , and . Extract the coefficient and identify in the model preceding (11).
Solution
The creation amplitude fixes , while the vacuum expectation fixes . Subtracting the vacuum term gives . Dividing by the creation amplitude gives . If one divides the unsubtracted diagonal matrix element instead, the spurious result is . Energy measurements are insensitive to this contamination of the probe operator.
2. Separate coincident levels by angular momentum
Count all states at dimension and two using (5). Identify which are scalar primaries and which are derivatives.
Solution
At dimension , either three quanta are excited, giving one scalar, or one quantum is excited, giving three spin-one states. These are the primary and . At dimension two, four quanta give the scalar primary ; one and one quantum give three spin-one states . Two quanta already have dimension three and do not belong to this level. Hence both levels have total multiplicity four, but their scalar and vector sectors have different conformal origins.
3. Estimate the spacing error without confusing it with a box error
Assume an observable obeys after the box has converged. Form an extrapolation from and , and apply it to the last two entries of the OPE-ratio column. Does this certify the interacting continuum theory?
Solution
The combination
cancels the leading stencil error. Using the retained unrounded values at and gives , close to . This is a check of the stated oscillator discretization, supported by its exact solution and the independent box variation. It says nothing by itself about tuning an interacting Hamiltonian, removing its angular or energy cutoff, or identifying its continuum operator mixture. Extrapolating at a fixed inadequate box would instead approach the wrong box problem.
References
- Pappadopulo, Duccio, Slava Rychkov, Johnny Espin, and Riccardo Rattazzi. “OPE Convergence in Conformal Field Theory.” Physical Review D 86 (2012), 105043. arXiv:1208.6449v3; DOI. Section 3.1, Eqs. (3.1)–(3.6), for the cylinder spectral expansion.
- Simmons-Duffin, David. “TASI Lectures on the Conformal Bootstrap.” In New Frontiers in Fields and Strings, World Scientific (2017), pp. 1–74. arXiv:1602.07982v1; DOI. Sections 6.3–6.4 and 7.2 for states, cylinder evolution, and normalized matrix elements. The finite oscillator discretization above is constructed for this example.
Scrollable formula. Use Left and Right arrow keys to reveal hidden content.
Scrollable table. Use Left and Right arrow keys to reveal hidden columns.